Leading Wholesale Trader of earth pit testing service, high voltage cable testing services, thermal imaging inspection service, electrical safety testing services, transformer testing and rccb/ rcd/ elcb testing from Thane.
₹ 350 / Piece Get Latest Price
| Service Duration | As per client scope |
| Site Location | Mumbai & Maharashtra |
| Area / Size | All sizes & Area |
| Start Date / Month | Depends on requirement |
| Feature | Durable, Environment Friendly |
| Payment Mode | Online (Bank Transfer) |
Minimum order quantity: 2 Piece
The main reason for doing earthing in electrical network is for the safety. When all metallic parts in electrical equipments are grounded then if the insulation inside the equipments fails, there are no dangerous voltages present in the equipment case. If the live wire touches the grounded case then the circuit is effectively shorted and fuse will immediately blow. When the fuse is blown then the dangerous voltages are away. From our extensive services, we are offering superior quality Earth Pit Testing services to our esteemed clients. We offer these services as per the various specifications of clients in compliance with the quality standards. In addition to this, clients can avail these services from us at market leading prices.
₹ 400 / Piece Get Latest Price
₹ 12000 / Day Get Latest Price
| Usage/Application | Electrical Switchgear Thermal Inspection |
| Location/City | Mumbai |
| Service Duration | As per client requirement |
| Services Required | As per client requirement |
| Frequency Of Requirement | Yearly |
Using Thermal Imaging Inspection Service, we can quickly locate temperature variations, which are often indications of underlying problems, and document them with detailed images in reports. By pinpointing potential sources of problems, you also save valuable inspection time and repair only what needs to be fixed, rather than performing repairs regardless of actual need. Repeated IR thermal temperature measurements of the same targets can determine whether repairs were successful and help anticipate future repairs. You can quickly locate temperature variations, which are often indications of underlying problems, and document them with detailed images in reports. By pinpointing potential sources of problems, you also save valuable inspection time and repair only what needs to be fixed, rather than performing repairs regardless of actual need. Repeated IR thermal temperature measurements of the same targets can determine whether repairs were successful and help anticipate future repairs.
FOB Price::20000
₹ 15000 / Sample Get Latest Price
| Equipment Type | Switchgear, Panel, Relay, Circuit Breaker, Motor, Transformer, Earthing, Generator, Cable, Battery Bank |
| Test Type | Contact Resistance, Insulation Test, Earth Test, Relay Test, Load Test |
| Voltage Class | Up To 33 Kv |
| Service Mode | On Site |
| Industry | Metro Rail, Power Plant, Substation, Refinery, Commercial, Residential, Manufacturing, Data Center, Cement Plant, Steel Plant |
| Standards Followed | IS, IEC, IEEE, CEA, CBIP |
| Shift Availability | 24x7 |
| Test Report | With Recommendation |
| Service Location | Pan India |
Electrical Safety Audit is a systematic inspection and assessment of electrical installations to identify potential hazards, non-compliance issues, and operational risks. Creative Energy Solution provides professional electrical safety auditing services for industries, commercial buildings, offices, hospitals, hotels, IT parks, residential complexes, schools, colleges, airports, railway stations, and data centers.
Our audit includes inspection of electrical panels, transformers, cables, earthing systems, protection devices, circuit breakers, and power distribution systems. We evaluate compliance with Indian Electricity Rules, NBC, IS standards, and fire safety regulations.
The audit process includes visual inspection, thermography scanning, load analysis, earthing resistance testing, insulation resistance testing, and power quality assessment. Our engineers identify risks such as overheating connections, improper earthing, overloaded circuits, loose terminations, poor cable management, and inadequate protection systems.
After completing the inspection, we provide a detailed audit report with risk categorization, photographic evidence, and actionable recommendations to improve electrical reliability and safety.
Electrical safety audits help organizations to reduce fire risks, prevent electrical failures, ensure regulatory compliance, improve system reliability, and protect personnel and assets.
₹ 20000 / Piece Get Latest Price
| Service Location | On-Site |
| Testing Type | Periodic/Condition |
| Type Of Tests | Vector Group, Ratio Test, Winding Resistance Test, Earth Resisance Test, BDV Test |
| Testing Service Level | Service Report will be provided |
| Usage/Application | Any |
| Test Interval | Yearly |
| Transformer Type | Any Type |
| Industry Type | Any Type |
| Number Of Units | 1 |
| Technique | As per standards |
₹ 1200 / Piece Get Latest Price
| Current Setting | 100mA |
| Type Of Testing Machines | Eddy Current Dynamometer |
| Packaging Type | Box |
| Display Type | Digital |
| Brand | Kyoritsu |
| Usage/Application | Industrial |
| Color | Blue |
Minimum order quantity: 5 Piece
Richa Gupta (Proprietor)
Creative Energy Solution
1st Floor, Shop No 3 ,Plot No 1, Clustor No 27, Ishwar Nagar, Digha, Near Mukund Company